This is the third part of our DIY Van Electrical Guide trilogy:
Made with in our van.
Sharing this tool with others is the best way to say thanks if you found it useful. Thanks for supporting us and for keeping this website alive! See you on the road š
Disclosure: This post contains affiliate links, which means that if you click a product link and buy anything from the merchant, we will receive a commission fee. The price you pay remains the same, affiliate link or not.
Van Electrical Calculator
- Size your battery bank, solar, alternator, shore, & inverter automagically or manually.
- Hover / tap any underlined wordUseful Tooltip! to reveal a useful tooltip.
- Start with our Electrical System Guide if you're new to this!
12V DC
SUMMER |
WINTER |
|||||
|---|---|---|---|---|---|---|
| LOADName of the appliance. | CUR (A)AVERAGE CURRENT (in amps) drawn during operation. Find this info on Google, product's website, owner's manual, technical sheet. |
HRS / DAY (h)How many HOURS per day this appliance is in operation. It's a guesstimate. |
DAILY USAGE (Ah)CURRENT x HOURS |
CUR (A)AVERAGE CURRENT (in amps) drawn during operation. Find this info on Google, product's website, owner's manual, technical sheet. |
HRS / DAY (h)How many HOURS per day this appliance is in operation. It's a guesstimate. |
DAILY USAGE (Ah)CURRENT x HOURS |
| TOTAL | ||||||
120V AC
SUMMER |
WINTER |
|||||||
|---|---|---|---|---|---|---|---|---|
| LOADName of the appliance. | PWR (W)MAX POWER (in watts) of the load. Find this info on Google, product's website, owner's manual, technical sheet. |
HRS / DAY (h)How many HOURS per day this appliance is in operation. It's a guesstimate. |
DAILY USAGE (Ah)[(POWER/12) x HOURS] / 0.85 |
INVThis column is used to size the inverter. Check all the appliances that you plan on using simultaneously. Note that the biggest load is automatically selected by the calculator. | PWR (W)MAX POWER (in watts) of the load. Find this info on Google, product's website, owner's manual, technical sheet. |
HRS / DAY (h)How many HOURS per day this appliance is in operation. It's a guesstimate. |
DAILY USAGE (Ah)[(POWER/12) x HOURS] / 0.85 |
INVThis column is used to size the inverter. Check all the appliances that you plan on using simultaneously. Note that the biggest load is automatically selected by the calculator. |
| TOTAL | ||||||||
Battery Type
Your Type
WINTER columns added. The calculator compares summer VS winter and works with the "worst" case scenario (most power usage).
Alternator
1- Size Your Main Components
Use the calculator above
Daily Energy Usage
? Ah
Battery Bank
? Ah
Solar Panels
? W
Solar Charger
?|?
Alternator Charge
? A
Shore Charger
? A
INVERTER
? W
Manual Mode Enabled.
Bold options = automagic values.
- DIAGNOSIS
- Does not compute. I need at least one load (12V DC or 120V AC) to size your system. Beep boop!
- Battery Bank: You need over 600Ah. Consider switching to Lithium instead.
- Battery Bank: You need over 600Ah and that's over my capacity. Beep Boop!
- Battery Bank: You need over 600Ah and that's over my capacity. Beep Boop!
- Battery Bank: Consider upgrading to a larger battery bank or adjusting your needs in 12V DC & 120V AC tables.
- SOLAR: The selected solar delivers too much current for this battery bank. Choose a smaller solar or upgrade the battery bank.
- Alternator: Consider limiting the charger's output current to 30A or upgrade the battery bank.
- Alternator: The selected charger is too big for your vehicle's alternator ("small" VS "regular" VS "Heavy-Duty/Dual"). Choose a smaller alternator charger.
- Shore: The selected charger delivers too much current for your battery bank. Choose a smaller charger or upgrade the battery bank.
- Inverter: You need over 3000W and the wiring diagram doesn't support that. Beep Boop! Make sure to only check loads that'll run simultaneously under "inv" column in "120V ac" table.
- Inverter: Consider choosing a smaller inverter or upgrading your battery bank. Your autonomy is very short with the actual selections.
- Inverter: The selected inverter draw too much current for this battery bank. choose a smaller inverter or upgrade the battery bank.
- Inverter: Consider upgrading to a larger inverter or adjusting your needs in the 120V AC table.
- Heads up! We had to adjust the battery bank, because we found no equivalent following your new selection.
- SHORE CHARGER: not needed with inverter/charger.
2- Size Your Wires, Fuses & Breakers
+ Wire Lengths & Terminals Calculator
Appropriate wire gauge (AWG) varies with length & load and, therefore, is unique to each installation. Our wiring diagram automatically sizes the wire gauge, fuses & breakers to ensure that your own system is safe and performs as it should. Bonus: it also calculates all the wire lengths & terminals that you'll need by type/gauge, which will make STEP 3 (customize your items list) super easy to complete. No other diagram does this!
- With the inputs you entered, we recommend downloading the HIGH-POWER wiring diagram.
3- Customize Your Items list
Fill these tables per your wiring diagram:
WIRES LENGTH (FT)
| AWG | 4/0 | 3/0 | 2/0 | 1/0 | 1 | 2 | 4 | 6 | 8 | 10 | 12 | 14 | 16 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| RED | |||||||||||||
| BLACK | |||||||||||||
| DUPLEX |
TERMINALS QUANTITY
| AWG | 4/0 | 3/0 | 2/0 | 1/0 | 1 | 2 | 4 | 6 | 8 | 10/12 | 14/16 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| #8 | |||||||||||
| #10 | |||||||||||
| 1/4 | |||||||||||
| 5/16 | |||||||||||
| 3/8 |
Cost EstimateIncludes everything on your Items List, except the 12V & 120V loads (appliances) and Tools. Prices on Amazon change frequently, so our estimate is subject to change.
$X,XXX USD
Heads up! There are now cheaper alternatives to Battle Born Batteries. You will find a list of our recommendations here: faroutride.com/battleborn-alternatives
Items List
The list below defines your entire electrical system. Click on "ADD ITEMS TO AMAZON CART" section-by-section; make sure that all the items are valid (links to Amazon products sometime change, please let us know if that's the case!), and make sure all items are in stock at the moment.
Main
| # | Item | Description | Quantity | View on Amazon |
| 1 | Terminal Fuse Block with Fuse 250A | Blue Sea (Catastrophic Fail Safe. Connects directly to battery post.) | 1 | View |
| 2 | System Switch | Blue Sea (Main System Switch) | 1 | View |
| 3 | Bus Bar (250A, 4 studs) | Blue Sea | 2 | View |
| 4 | Cover for Bus Bar (for 250A 4 studs) | Protect the Bus Bar | 2 | View |
| 5 | 40A Breaker/Switch, Surface Mount | Between Fuse Block and Bus Bar | 1 | View |
| 6 | Fuse Block (12 circuits) | Blue Sea (12V Distribution Panel) | 1 | View |
| 7 | Fuses Kit | Assorted Fuses (2A 3A 5A 7.5A 10A 15A 20A 25A 30A 35A) | 1 | View |
| 8 | Battery Monitor | Victron BMV-712 with BlueTooth | 1 | View |
Main
| # | Item | Description | Quantity | View on Amazon |
| 1 | Class T Fuse, 300A | Blue Sea (Catastrophic Fail Safe) | 1 | View |
| 2 | Class T Fuse Block | Blue Sea (Holds the Class T Fuse) | 1 | View |
| 3 | System Switch | Blue Sea (Main System Switch) | 1 | View |
| 4 | Bus Bar (600A, 4 studs) | Blue Sea | 2 | View |
| 5 | Cover for Bus Bar (for 600A 4 studs) | Protect the Bus Bar | 2 | View |
| 6 | 40A Breaker/Switch, Surface Mount | Between Fuse Block and Bus Bar | 1 | View |
| 7 | Fuse Block (12 circuits) | Blue Sea (12V Distribution Panel) | 1 | View |
| 8 | Fuses Kit | Assorted Fuses (2A 3A 5A 7.5A 10A 15A 20A 25A 30A 35A) | 1 | View |
| 9 | Battery Monitor | Victron BMV-712 with BlueTooth | 1 | View |
Main
| # | Item | Description | Quantity | View on Amazon |
| 1 | Class T Fuse, 400A | Blue Sea (Catastrophic Fail Safe) | 1 | View |
| 2 | Class T Fuse Block | Blue Sea (Holds the Class T Fuse) | 1 | View |
| 3 | System Switch | Blue Sea (Main System Switch) | 1 | View |
| 4 | Bus Bar (600A, 4 studs) | Blue Sea | 2 | View |
| 5 | Cover for Bus Bar (for 600A 4 studs) | Protect the Bus Bar | 2 | View |
| 6 | 40A Breaker/Switch, Surface Mount | Between Fuse Block and Bus Bar | 1 | View |
| 7 | Fuse Block (12 circuits) | Blue Sea (12V Distribution Panel) | 1 | View |
| 8 | Fuses Kit | Assorted Fuses (2A 3A 5A 7.5A 10A 15A 20A 25A 30A 35A) | 1 | View |
| 9 | Battery Monitor | Victron BMV-712 with BlueTooth | 1 | View |
Battery
Nothing to show here. You need to enter some 12V and/or 120V loads, or choose a battery bank if you are in manual mode.
Battery
| # | Item | Description | Quantity | View on Amazon |
| 1 | AGM 100 Ah | Renogy AGM 100 Ah 12V | 1 | View |
Battery
| # | Item | Description | Quantity | View Link |
| 1 | AGM 200 Ah | Renogy AGM 200 Ah 12V | 1 | View |
Battery
Battery
Battery
Battery
Battery
| # | Item | Description | Quantity | View on Amazon |
| 1 | LiFePO4 100 Ah | Battle Born LiFePO4 100 Ah 12V | 1 | View |
Battery
Battery
| # | Item | Description | Quantity | View on Amazon |
| 1 | LiFePO4 270 Ah | Battle Born LiFePO4 270 Ah 12V | 1 | View |
Battery
Battery
Battery
Battery
Battery
Battery
| # | Item | Description | Quantity | View on Amazon |
| 1 | LiFePO4 100 Ah | Renogy LiFePO4 100 Ah 12V | 1 | View |
Battery
| # | Item | Description | Quantity | View on Amazon |
| 1 | LiFePO4 200 Ah | Renogy LiFePO4 200 Ah 12V | 1 | View |
Battery
Battery
Battery
Battery
Battery
Battery
Battery
Battery
Battery
Battery
Battery
Battery
Battery
Battery
Battery
Battery
Battery
Battery
Solar
Nothing to show here. You can add solar charging later if you change your mind, as our wiring diagram allows for future expansion!
Solar
| # | Item | Description | Quantity | View on Amazon |
| 1 | 100W Solar | Renogy 100W Mono Panel | 1 | View |
| 2 | Extension Cables, 8 AWG, 15 ft Red + 15 ft Black | With MC4 Connectors | 1 | View |
| 3 | Double Cable Entry Gland | For 8 AWG or 10 AWG Cable | 1 | View |
| 4 | 25A Breaker/Switch, Surface Mount | Between Panels and MPPT Charger | 1 | View |
| 5 | MPPT Solar Charger | Victron 75|15 SmartSolar MPPT | 1 | View |
| 6 | 25A Breaker/Switch, Surface Mount | Between MPPT Charger & Battery | 1 | View |
Solar
| # | Item | Description | Quantity | View on Amazon |
| 1 | 180W Solar | NewPowa 180W Mono Panel | 1 | View |
| 2 | Extension Cables, 8 AWG, 15 ft Red + 15 ft Black | With MC4 Connectors | 1 | View |
| 3 | Double Cable Entry Gland | For 8 AWG or 10 AWG Cable | 1 | View |
| 4 | 25A Breaker/Switch, Surface Mount | Between Panels and MPPT Charger | 1 | View |
| 5 | MPPT Solar Charger | Victron 75|15 SmartSolar MPPT | 1 | View |
| 6 | 25A Breaker/Switch, Surface Mount | Between MPPT Charger & Battery | 1 | View |
Solar
| # | Item | Description | Quantity | View on Amazon |
| 1 | 200W Solar | Renogy 100W Mono Panel | 2 | View |
| 2 | Extension Cables, 8 AWG, 15 ft Red + 15 ft Black | With MC4 Connectors | 1 | View |
| 3 | Double Cable Entry Gland | For 8 AWG or 10 AWG Cable | 1 | View |
| 4 | 25A Breaker/Switch, Surface Mount | Between Panels and MPPT Charger | 1 | View |
| 5 | MPPT Solar Charger | Victron 75|15 SmartSolar MPPT | 1 | View |
| 6 | 25A Breaker/Switch, Surface Mount | Between MPPT Charger & Battery | 1 | View |
Solar
| # | Item | Description | Quantity | View on Amazon |
| 1 | 300W Solar | Renogy 100W Mono Panel | 3 | View |
| 2 | Extension Cables, 8 AWG, 15 ft Red + 15 ft Black | With MC4 Connectors | 1 | View |
| 3 | Double Cable Entry Gland | For 8 AWG or 10 AWG Cable | 1 | View |
| 4 | 40A Breaker/Switch, Surface Mount | Between Panels and MPPT Charger | 1 | View |
| 5 | MPPT Solar Charger | Victron 100|30 SmartSolar MPPT | 1 | View |
| 6 | 40A Breaker/Switch, Surface Mount | Between MPPT Charger & Battery | 1 | View |
Solar
| # | Item | Description | Quantity | View on Amazon |
| 1 | 360W Solar | NewPowa 180W Mono Panel | 2 | View |
| 2 | Extension Cables, 8 AWG, 15 ft Red + 15 ft Black | With MC4 Connectors | 1 | View |
| 3 | Double Cable Entry Gland | For 8 AWG or 10 AWG Cable | 1 | View |
| 4 | 40A Breaker/Switch, Surface Mount | Between Panels and MPPT Charger | 1 | View |
| 5 | MPPT Solar Charger | Victron 100|30 SmartSolar MPPT | 1 | View |
| 6 | 40A Breaker/Switch, Surface Mount | Between MPPT Charger & Battery | 1 | View |
Solar
| # | Item | Description | Quantity | View on Amazon |
| 1 | 540W Solar | NewPowa 180W Mono Panel | 3 | View |
| 2 | Extension Cables, 8 AWG, 15 ft Red + 15 ft Black | With MC4 Connectors | 1 | View |
| 3 | Double Cable Entry Gland | For 8 AWG or 10 AWG Cable | 1 | View |
| 4 | 60A Breaker/Switch, Surface Mount | Between Panels and MPPT Charger | 1 | View |
| 5 | MPPT Solar Charger | Victron 100|50 SmartSolar MPPT | 1 | View |
| 6 | 60A Breaker/Switch, Surface Mount | Between MPPT Charger & Battery | 1 | View |
Solar
| # | Item | Description | Quantity | View on Amazon |
| 1 | 720W Solar | NewPowa 180W Mono Panel | 4 | View |
| 2 | Extension Cables, 8 AWG, 15 ft Red + 15 ft Black | With MC4 Connectors | 1 | View |
| 3 | Double Cable Entry Gland | For 8 AWG or 10 AWG Cable | 1 | View |
| 4 | 70A Breaker/Switch, Surface Mount | Between Panels and MPPT Charger | 1 | View |
| 5 | MPPT Solar Charger | Victron 150|60 SmartSolar MPPT | 1 | View |
| 6 | 70A Breaker/Switch, Surface Mount | Between MPPT Charger & Battery | 1 | View |
Solar
| # | Item | Description | Quantity | View on Amazon |
| 1 | 100W Solar | Renogy 100W Mono Panel | 1 | View |
| 2 | Extension Cables, 8 AWG, 15 ft Red + 15 ft Black | With MC4 Connectors | 1 | View |
| 3 | Double Cable Entry Gland | For 8 AWG or 10 AWG Cable | 1 | View |
| 4 | 30A Breaker/Switch, Surface Mount | Between Panels and MPPT Charger | 1 | View |
| 5 | MPPT Solar Charger | Renogy Rover LI 20A MPPT | 1 | View |
| 6 | 30A Breaker/Switch, Surface Mount | Between MPPT Charger & Battery | 1 | View |
Solar
| # | Item | Description | Quantity | View on Amazon |
| 1 | 180W Solar | NewPowa 180W Mono Panel | 1 | View |
| 2 | Extension Cables, 8 AWG, 15 ft Red + 15 ft Black | With MC4 Connectors | 1 | View |
| 3 | Double Cable Entry Gland | For 8 AWG or 10 AWG Cable | 1 | View |
| 4 | 30A Breaker/Switch, Surface Mount | Between Panels and MPPT Charger | 1 | View |
| 5 | MPPT Solar Charger | Renogy Rover LI 20A MPPT | 1 | View |
| 6 | 30A Breaker/Switch, Surface Mount | Between MPPT Charger & Battery | 1 | View |
Solar
| # | Item | Description | Quantity | View on Amazon |
| 1 | 200W Solar | Renogy 100W Mono Panel | 2 | View |
| 2 | Extension Cables, 8 AWG, 15 ft Red + 15 ft Black | With MC4 Connectors | 1 | View |
| 3 | Double Cable Entry Gland | For 8 AWG or 10 AWG Cable | 1 | View |
| 4 | 30A Breaker/Switch, Surface Mount | Between Panels and MPPT Charger | 1 | View |
| 5 | MPPT Solar Charger | Renogy Rover LI 20A MPPT | 1 | View |
| 6 | 30A Breaker/Switch, Surface Mount | Between MPPT Charger & Battery | 1 | View |
Solar
| # | Item | Description | Quantity | View on Amazon |
| 1 | 300W Solar | Renogy 100W Mono Panel | 3 | View |
| 2 | Extension Cables, 8 AWG, 15 ft Red + 15 ft Black | With MC4 Connectors | 1 | View |
| 3 | Double Cable Entry Gland | For 8 AWG or 10 AWG Cable | 1 | View |
| 4 | 40A Breaker/Switch, Surface Mount | Between Panels and MPPT Charger | 1 | View |
| 5 | MPPT Solar Charger | Renogy Rover LI 30A MPPT | 1 | View |
| 6 | 40A Breaker/Switch, Surface Mount | Between MPPT Charger & Battery | 1 | View |
Solar
| # | Item | Description | Quantity | View on Amazon |
| 1 | 360W Solar | NewPowa 180W Mono Panel | 2 | View |
| 2 | Extension Cables, 8 AWG, 15 ft Red + 15 ft Black | With MC4 Connectors | 1 | View |
| 3 | Double Cable Entry Gland | For 8 AWG or 10 AWG Cable | 1 | View |
| 4 | 40A Breaker/Switch, Surface Mount | Between Panels and MPPT Charger | 1 | View |
| 5 | MPPT Solar Charger | Renogy Rover LI 30A MPPT | 1 | View |
| 6 | 40A Breaker/Switch, Surface Mount | Between MPPT Charger & Battery | 1 | View |
Solar
| # | Item | Description | Quantity | View on Amazon |
| 1 | 540W Solar | NewPowa 180W Mono Panel | 3 | View |
| 2 | Extension Cables, 8 AWG, 15 ft Red + 15 ft Black | With MC4 Connectors | 1 | View |
| 3 | Double Cable Entry Gland | For 8 AWG or 10 AWG Cable | 1 | View |
| 4 | 70A Breaker/Switch, Surface Mount | Between Panels and MPPT Charger | 1 | View |
| 5 | MPPT Solar Charger | Renogy Rover LI 60A MPPT | 1 | View |
| 6 | 70A Breaker/Switch, Surface Mount | Between MPPT Charger & Battery | 1 | View |
Solar
| # | Item | Description | Quantity | View on Amazon |
| 1 | 720W Solar | NewPowa 180W Mono Panel | 4 | View |
| 2 | Extension Cables, 8 AWG, 15 ft Red + 15 ft Black | With MC4 Connectors | 1 | View |
| 3 | Double Cable Entry Gland | For 8 AWG or 10 AWG Cable | 1 | View |
| 4 | 70A Breaker/Switch, Surface Mount | Between Panels and MPPT Charger | 1 | View |
| 5 | MPPT Solar Charger | Renogy Rover LI 60A MPPT | 1 | View |
| 6 | 70A Breaker/Switch, Surface Mount | Between MPPT Charger & Battery | 1 | View |
Alternator
Nothing to show here. You can add alternator charging later if you change your mind, as our wiring diagram allows for future expansion!
Alternator
Alternator
*Item #1 (BBW12120) is currently not available on Amazon, so you'll have to buy it separately on eBay.
Shore
Nothing to show here. You can add shore charging later if you change your mind, as our wiring diagram allows for future expansion!
Shore
Shore
Shore
Inverter
Nothing to show here. You can add an inverter later if you change your mind, as our wiring diagram allows for future expansion!Ā
Inverter
Optional Items:
Inverter
Optional Items:
Inverter
Optional Items:
Inverter
| # | Item | Description | Quantity | View on Amazon |
| 1 | 2000W Inverter | Samlex NTX-2000-12 Pure Sine | 1 | View |
| 2 | Remote Control for Inverter | Included |
Optional Items:
Inverter
Optional Items:
Inverter
Optional Items:
Inverter
Optional Items:
Inverter
| # | Item | Description | Quantity | View on Amazon |
| 1 | 2000W Inverter | Renogy 2000W Pure Sine | 1 | View |
| 2 | Remote Control for Inverter | Included |
Optional Items:
Inverter/Charger
| # | Item | Description | Quantity | View on Amazon |
| 1 | 2000W Inverter/Charger | Victron Multiplus Compact 12|2000|80 | 1 | View |
| 2 | Remote Control for Inverter | Victron Digital Multi Control 200/200A GX | 1 | View |
| 3 | Class T Fuse, 300A | Blue Sea (To protect inverter’s cable) | 1 | View |
| 4 | Class T Fuse Block | Blue Sea (Holds the Class T Fuse) | 1 | View |
| 5 | 30A Shore Inlet | Furrion 30A Marine Power Smart Inlet | 1 | View |
| 6 | 30A AC Main | Breaker Between Power Inlet and Inverter/Charger | 1 | View |
| 7 | 120V AC Distribution Panel (4 Positions*) | Blue Sea Panel: AC Main + 4 Positions* | 1 | View |
| 8 | 10/3 AWG Triplex AC Marine Wire | Between power inlet & inverter/charger | 1 | View |
| 9 | 6/3 AWG Triplex AC Marine Wire | Between inverter/charger & AC distribution panel | 1 | View |
| 10 | 120V AC GFCI Outlet | GFCI, 15A | 1 | View |
| 11 | 14/3 AWG Triplex AC Marine Wire | To wire load that requires 15A or 10A breaker | 1 | View |
Optional Items:
| # | Optional Item | Description | View on Amazon |
| 1 | 50A Breaker (Double-Pole) | To upgrade 120V AC distribution panel to 50A instead of 30A | View |
| 2 | 20A Breaker | For load that requires 20A breaker (e.g. A/C) | View |
| 3 | 10A Breaker | For load that requires 10A breaker | View |
| 4 | 120V AC Distribution Panel (6 Positions*) | *6 Positions panel is sometimes cheaper, check it! | View |
| 5 | 12/3 AWG Triplex AC Marine Wire | To wire load that requires 20A breaker (e.g. A/C) | View |
Inverter/Charger
| # | Item | Description | Quantity | View on Amazon |
| 1 | 2000W Inverter/Charger | Victron Multiplus Compact 12|2000|80 | 1 | View |
| 2 | Remote Control for Inverter | Victron Digital Multi Control 200/200A GX | 1 | View |
| 3 | Class T Fuse, 300A | Blue Sea (To protect inverter’s cable) | 1 | View |
| 4 | Class T Fuse Block | Blue Sea (Holds the Class T Fuse) | 1 | View |
| 5 | 30A Shore Inlet | Furrion 30A Marine Power Smart Inlet | 1 | View |
| 6 | 30A AC Main | Breaker Between Power Inlet and Inverter/Charger | 1 | View |
| 7 | 120V AC Distribution Panel (4 Positions*) | Blue Sea Panel: AC Main + 4 Positions* | 1 | View |
| 8 | 10/3 AWG Triplex AC Marine Wire | Between power inlet & inverter/charger | 1 | View |
| 9 | 6/3 AWG Triplex AC Marine Wire | Between inverter/charger & AC distribution panel | 1 | View |
| 10 | 120V AC GFCI Outlet | GFCI, 15A | 1 | View |
| 11 | 14/3 AWG Triplex AC Marine Wire | To wire load that requires 15A or 10A breaker | 1 | View |
Optional Items:
| # | Optional Item | Description | View on Amazon |
| 1 | 50A Breaker (Double-Pole) | To upgrade 120V AC distribution panel to 50A instead of 30A | View |
| 2 | 20A Breaker | For load that requires 20A breaker (e.g. A/C) | View |
| 3 | 10A Breaker | For load that requires 10A breaker | View |
| 4 | 120V AC Distribution Panel (6 Positions*) | *6 Positions panel is sometimes cheaper, check it! | View |
| 5 | 12/3 AWG Triplex AC Marine Wire | To wire load that requires 20A breaker (e.g. A/C) | View |
Inverter/Charger
| # | Item | Description | Quantity | View on Amazon |
| 1 | 3000W Inverter/Charger | Victron Multiplus Compact 12|3000|120 | 1 | View |
| 2 | Remote Control for Inverter | Victron Digital Multi Control 200/200A GX | 1 | View |
| 3 | Class T Fuse, 400A | Blue Sea (To protect inverter’s cable) | 1 | View |
| 4 | Class T Fuse Block | Blue Sea (Holds the Class T Fuse) | 1 | View |
| 5 | 30A Shore Inlet | Furrion 30A Marine Power Smart Inlet | 1 | View |
| 6 | 30A AC Main | Breaker Between Power Inlet and Inverter/Charger | 1 | View |
| 7 | 120V AC Distribution Panel (4 Positions*) | Blue Sea Panel: AC Main + 4 Positions* | 1 | View |
| 8 | 10/3 AWG Triplex AC Marine Wire | Between power inlet & inverter/charger | 1 | View |
| 9 | 6/3 AWG Triplex AC Marine Wire | Between inverter/charger & AC distribution panel | 1 | View |
| 10 | 120V AC GFCI Outlet | GFCI, 15A | 1 | View |
| 11 | 14/3 AWG Triplex AC Marine Wire | To wire load that requires 15A or 10A breaker | 1 | View |
Optional Items:
| # | Optional Item | Description | View on Amazon |
| 1 | 50A Breaker (Double-Pole) | To upgrade 120V AC distribution panel to 50A instead of 30A | View |
| 2 | 20A Breaker | For load that requires 20A breaker (e.g. A/C) | View |
| 3 | 10A Breaker | For load that requires 10A breaker | View |
| 4 | 120V AC Distribution Panel (6 Positions*) | *6 Positions panel is sometimes cheaper, check it! | View |
| 5 | 12/3 AWG Triplex AC Marine Wire | To wire load that requires 20A breaker (e.g. A/C) | View |
Inverter/Charger
| # | Item | Description | Quantity | View on Amazon |
| 1 | 3000W Inverter/Charger | Victron Multiplus Compact 12|3000|120 | 1 | View |
| 2 | Remote Control for Inverter | Victron Digital Multi Control 200/200A GX | 1 | View |
| 3 | Class T Fuse, 400A | Blue Sea (To protect inverter’s cable) | 1 | View |
| 4 | Class T Fuse Block | Blue Sea (Holds the Class T Fuse) | 1 | View |
| 5 | 30A Shore Inlet | Furrion 30A Marine Power Smart Inlet | 1 | View |
| 6 | 30A AC Main | Breaker Between Power Inlet and Inverter/Charger | 1 | View |
| 7 | 120V AC Distribution Panel (4 Positions*) | Blue Sea Panel: AC Main + 4 Positions* | 1 | View |
| 8 | 10/3 AWG Triplex AC Marine Wire | Between power inlet & inverter/charger | 1 | View |
| 9 | 6/3 AWG Triplex AC Marine Wire | Between inverter/charger & AC distribution panel | 1 | View |
| 10 | 120V AC GFCI Outlet | GFCI, 15A | 1 | View |
| 11 | 14/3 AWG Triplex AC Marine Wire | To wire load that requires 15A or 10A breaker | 1 | View |
Optional Items:
| # | Optional Item | Description | View on Amazon |
| 1 | 50A Breaker (Double-Pole) | To upgrade 120V AC distribution panel to 50A instead of 30A | View |
| 2 | 20A Breaker | For load that requires 20A breaker (e.g. A/C) | View |
| 3 | 10A Breaker | For load that requires 10A breaker | View |
| 4 | 120V AC Distribution Panel (6 Positions*) | *6 Positions panel is sometimes cheaper, check it! | View |
| 5 | 12/3 AWG Triplex AC Marine Wire | To wire load that requires 20A breaker (e.g. A/C) | View |
Wires
Nothing to show here. You need to fill the “Wires” table in the calculator above.
Terminals
Nothing to show here. You need to fill the “Terminals” table in the calculator above.
Hardware
| # | Item | Description | Quantity | View on Amazon |
| 1 | Heat Shrink Butt Connector, Ancor Marine | To connect to Loads (75 Pack Kit) | 1 | View |
| 2 | Heat Shrink Disconnect, 10-12 AWG Cable, 1/4″ Tab, Female |
To connect to certain loads (i.e. 12V Sockets) , to make “removable” connections (i.e. Fridge, LEDs) and to connect cable of different gauge together (i.e. LED Dimmer) (25 Pack) |
1 | View |
| 3 | Heat Shrink Disconnect, 10-12 AWG Cable, 1/4″ Tab, Male | 1 | View | |
| 4 | Heat Shrink Disconnect, 14-16 AWG Cable, 1/4″ Tab, Female | 1 | View | |
| 5 | Heat Shrink Disconnect, 14-16 AWG Cable, 1/4″ Tab, Male | 1 | View | |
| 6 | Heat Shrink Disconnect, 18-22 AWG Cable, 1/4″ Tab, Male | 1 | View | |
| 7 | 3M Scotchlok Quick Splice with Gel (14 AWG stranded) | We used that to parallel our LED lights (25 Pack) | 1 | View |
| 8 | Heat Shrink Tubing Kit (with adhesive) | To protect lug after crimping | 1 | View |
| 9 | Split Loom Tubing, 3/8″ diameter 25 feet | To protect wire bundles | 1 | View |
| 10 | Split Loom Tubing, 1/2″ diameter 25 feet | To protect wire bundles | 1 | View |
| 11 | Split Loom Tubing, 3/4″ diameter 10 feet | To protect wire bundles | 1 | View |
| 12 | Nylon Cable Clamps Kit | To secure cable/split-loom to wood | 1 | View |
| 13 | Zip Tie Mount with Adhesive | To secure cable/split-loom to metal | 1 | View |
| 14 | Nylon Zip Ties Kit | To secure cable/split-loom | 1 | View |
| 15 | Rubber Grommet Kit | To protect wire from sharp edge (going through metal hole) | 1 | View |
12V Loads
These are the appliances we personally use in our van:
| # | Item | Quantity | Buy Link | More Info |
| 1 | Maxxair 6200K Roof Fan | 1 | Amazon | Fan Installation |
| 2 | LED Ceiling Lights (Dimmable) | 3 | Amazon | |
| 3 | PWM Dimmer for LED Lights, 12V, Slider | 1 | Amazon | |
| 4 | Blue Sea 12V Socket | 4 | Amazon | Electrical System Guide |
| 5 | Shurflo Revolution Water Pump, 3 GPM | 1 | Amazon | |
| 6 | ON/OFF Switch for Water Pump | 1 | Amazon | |
| 7 | Webasto Air Top 2000 STC Gasoline Heater | 1 | Amazon | Webasto Installation |
| 8 | Propex HS2000 Propane Heater | 1 | Dealers | Propex Installation |
| 9 | Novakool R5810 Fridge, 12V only | 1 | Campervan-HQ | Fridge Guide |
| 10 | Sirocco ii Gimbal Fan, 12V | 1 | Amazon | Sirocco ii Installation / Review |
| 11 | Natureās Head Composting Toilet | 1 | Amazon | Toilet Installation |
| 12 | Propane Solenoid Shutoff Valve | 1 | Amazon | |
| 13 | ON/OFF Switch for Propane Solenoid | 1 | Amazon |
Tools
These are essential to build your electrical system. Do NOT cheap out on tools (e.g. using pliers to crimp), or you'll compromise the performance and safety of your system.
| # | Item | Description | QTY | View on Amazon |
| 1 | Cable Cutter (up to 4/0 AWG) | For large gauge cables | 1 | View |
| 2 | Wire & Cable Cutter (2/0 – 22 AWG) | Nothing to add! | 1 | View |
| 3 | Wire & Cable Stripper (4/0 – 20 AWG) | Nothing to add! | 1 | View |
| 4 | Hydraulic Crimping Tool (4/0 – 10 AWG) | Provides adequate, repeatable results for larger gauge lugs. | 1 | View |
| 5 | Crimping Tool, Single-Crimp (8 – 22 AWG) | Single-Crimp should be used with Heat Shrink connectors to prevent tearing the insulation and loosening the watertight connection (corrosion prevention) | 1 | View |
| 6 | Heat Gun for Heat Shrink Connectors | 1800W, Variable Temperature Control | 1 | View |
| 7 | Digital Multimeter (Voltage, Current, Continuity, Resistance) | You don’t need it until you need it! Your friend when you need to troubleshoot… | 1 | View |






Does the cost estimate include all items listed in āitems listā? Thanks!
In the 120V AC calculator tool, we added an induction stove (1800W), took out all other sources. We would likely use this on average 30 mi/day at the 900W setting. Our calculation shows 900W/120V * .5hrs = 3.75 amp hours. The calculator is showing 44.1 amp hours. What are we missing here?
Thanks!
Your energy source (battery) is 12V, so 900W/12V/.85 (inverter generally have around 85% efficiency). Remember that you draw 10 times the amps on the 12V side! Cheers š
Does your calculator design the electrical system based on a 4-day off-grid timeframe? I ask this because you mentioned that your goal was 4 days off-grid. What % of that time is assumed using the alternator?
Hi Jason,
All the calculations are detailed on this page: https://faroutride.com/van-electrical-sizing/
Cheers
Hi,
Would love to buy the electric wiring module but am wondering whether this also works for 220V (EU) and does it have links to EU products?
Thanks
Lisa
Unfortunately no, this is for 120V.
Bonjour Antoine!
Tout d’abord, merci de partager toutes ces infos, c’est trĆØs apprĆ©ciĆ©.
J’ai reƧu un panneau solaire de 275w d’un ami et je compte l’utiliser pour mon camper van. Cependant, le wattage est un peu haut pour mes besoins Ć©nergĆ©tiques; votre calculatrice solaire me recommande plutĆ“t 175w. Je me demande seulement si c’est sĆ©curitaire d’utiliser le panneau avec une batterie plus petite, disons 100ah?
Je planifie acheter AGM 12V, avec un contrƓleur de charge MPPT.
Merci beaucoup!
Ćdouard
Pas de souci, ca devrait ĆŖtre correct. Faite passer le calculator en mode “MANUEL” et choisissez 100AH AGM comme batterie et 200W comme solaire (ou plus); si il y’a un problĆØme, un message s’affiche dans la section “DIAGNOSIS”.
Bonne chance!
Antoine,
Thanks for all your work on this site. It’s been a tremendous resource.
The guide on this page recommended lithium batteries and the samlex SEC-UL battery charger for shore power. The product description for the charger does not mention its compatible with lithium batteries however. Do you see any issue with using this combination?
Thanks.
Lithium can be charged with AGM settings, since the voltage profiles are the same:
“You can use any standard charger, solar or wind charge controller to charge our LIFEPO4 deep cycle battery. There are some chargers and controllers that are programmable to get full usage out of your battery, but most will have an AGM setting which normally bulk charges about 14.4 volts and floats at 13.6 volts. These levels are great for your Battle Born battery.”
Source: https://battlebornbatteries.com/charging-lifepo4-batteries/
Cheers!
Salut Antoine,
First, this site is amazing and so is your FB Group. I’m learning all the basics here, but I’ve been told to go another route and purchase directly on AliExpress (Ex: https://www.aliexpress.com/item/4000746859489.html?spm=a2g0o.productlist.0.0.68d97270gTlSMB&algo_pvid=faccf03d-1de1-4427-a3e1-00f49b300139&algo_expid=faccf03d-1de1-4427-a3e1-00f49b300139-8&btsid=0ab6f83a15906140727713587e1e8a&ws_ab_test=searchweb0_0,searchweb201602_,searchweb201603)… Seems alot cheaper, and good stuff… What do you guys think?
You get what you pay for; cheap and good rarely go well together. I always recommend to go for branded products, backed up by a warranty and customer service. Especially for critical components such as the electrical system where safety counts.
I feel like I’m in electrical boot camp. Trying to synthesize all the information related to van system. I’m starting to understand how it all fits together but 2 questions for today. What are the terminal fuses and main switch functions in the faroutride wiring diagram and is this something needed in our simpler set up? Diagram in facebook post (DIY Cargo Van Conversion Help | Campervan Builders Forum) 5.20.20
Thank you for creating all this information! Massive help. I am working on sizing wires through the blue seas app. As a means of understanding and checking things, I have plugged in some of your info from your build. I can’t get it to size the wires you listed.
Example – Your fan – .3A @20hr at 30ft recommends 18 awg wire. You used 14 awg. ( I have tested several of your other scenarios and can not get the gauge to be similar.
Am I plugging something in wrong, or is there a different wire size calculator used? Thanks.
It is not really recommended to use 18AWG as it is weak (because of the small diameter). Then, the next size would be 16AWG… but we choose 14AWG, so we don’t have to order too many different size of wire (to save $$$). It is totally acceptable to use bigger wire than needed (but it’s not acceptable to use smaller one).
Hope that helps!
Excellent website! I appreciate you guys sharing all of your knowledge and troubleshooting!!
One question I didnāt see anywhere else (maybe I missed it). How did you get your wire from alternator to battery? Under van in conduit? Inside van under flooring? Thanks!!
Andy
There is no need to connect “directly” to the alternator; it is actually done by connecting to the starter battery. It is documented here: https://faroutride.com/b2b-review/
cheers
I’ve got two questions.
1. What is your take on charging equipment that uses 5v? For instance, the wifi-extender we are planning to use is 5vdc.
2. Do you have a way to limit ‘vampire drain’ but shutting off sections of your system overnight? I just don’t see the sense in letting something like a wifi-extender drain power, even in standby mode, while I’m sleeping.
Hi!
1. I would use a 12V to 5V converter: https://amzn.to/2O1PBDN
2. We don’t have any appliance that stays on stanby (except maybe the JetPack, but we turn it off at night. Oh and the SensorPush Gateway as well, but I don’t really worry about that…), but adding a switch to a section of your system would definitely works!
Cheers!
Hello!
This 3 part electrical series has been so helpful in wrapping my head around this as a total beginner, so THANK YOU! I’ve created my own diagram based off of yours and I have one question. Did you include a ground? I’ve seen it connecting at the negative bus bar, but I’ve also read some contradicting opinions. Any help would be much appreciated.
Thank you again!
Amanda
The ground it the connection between our Negative Bus Bar & the van chassis (see faroutride.com/b2b-review/). If you don’t charge from the alternator, you don’t need to ground to the vehicle chassis!
Antione.
Love your site…definitely one of the best and of great help to me in doing my 2005 chevy extended van conversion here on Vancouver Island. I’m just finishing the building of the actual hi-top now and then will be facing the electrical side of the project. The most daunting. I have a question though. I am interested in using your wiring plan system but there are a number of changes I would like to make in equipment, to suit my small budget. Does the planning set up your wiring diagram allow for changes in equipment rather than some of the choices given? Can I somehow swap one for another and have the wiring diagram produced show these changes? I look forward to your response. All the best you two. Enjoy life to the full and thanks for your help.
The diagram actually is “static”; it doesn’t update according to your choices. Sure it would be nice, but it’s way above our coding skills!! You can still change some of the equipment and use the diagram as a baseline; the concept would be the same.
Hope that helps!
Antoine
Antonie,
First off, amazing site. It is streamlining my build a ton.
So I did catch on that the wiring diagram was for YOUR build, and not updated based on the calculator that I did. Regardless, the wiring diagram is a huge help. Where I am getting somewhat stumped now is sizing the breaker, bus bar, fuse block, etc. I do notice that the “Items List” does change as I change selections on the calculator. Is it safe to say, if the calculator is done properly, the “Items List” is updated based on what I input on the calculator?
Thanks much!!
That’s correct. The calculator outputs exactly what you need depending on your inputs!
I chose a Lithium set up, but I see the Samlex SEC-1280UL 12V doesn’t mention it working automatically with Lithium batteries. Does it support Lithium?
Because they need the same charging voltage, Lithium batteries can be charged with the “AGM” settings of any smart charger (like the Samlex):
“There are some chargers and controllers that are programmable to get full usage out of your battery, but most will have an AGM setting which normally bulk charges about 14.4 volts and floats at 13.6 volts. These levels are great for your Battle Born battery.”
https://battlebornbatteries.com/charging-lifepo4-batteries/
Cheers!
Thanks for the help. Just wanted to let you know the B2B is wire wrong according to the sterling manual. The negatives arenāt hooked up right. The manual also recommends larger fuses than those shown. Just a heads up. Great site!
Hi Jason,
Negatives are as per manual, take a second look. That’s how our own B2B is installed and we confirm it works!
Fuse are sized per manual V51 (70A); they changed the fuse size recently (100A) for some reason (V68). Can confirm the 70A works!
Have a good one š
Antoine
Super helpful. Thank you.
A recommendation: The download for the wiring diagrams says “download YOUR wiring diagram and tutorial.” It should say “download OUR wiring diagram and tutorial.” After working through the thorough step-by-step calculator that you’ve created, I excepted this wiring diagram to represent the selections that I made for the system that I want to create. Instead, I paid $30 for a diagram that is a representation of the system that you created for your own van. The diagram of your system is available for reference (at no charge) on the first page of your Electrical Systems Design. Although I appreciate the time and energy that you put into gathering all of this information, I’m a bit frustrated that I purchased a product that was different that what you claimed it would be.
We agree with you. We replaced “YOUR” with “OUR” and added this note near the download button:
“*At the moment, the wiring diagram represent the electrical system as we built it for our van. Our goal is to make it so it represent the electrical system as YOU designed it using this calculator, but we have a few technological challenges to overcome to make it happen… Meanwhile, our wiring diagram can be used to build any variation given by this calculator! :)”
How does this sound?
Freaking great site and calculator.
Thanks!! š
Very nice feature but it doesn’t quite cover what I am considering. I’m currently looking at an all-electric system, no propane with 240V appliances, 600Ah Lithium battery bank, 3000W inverter, and a Nations Starter and Alternator 280A dual alternator kit for charging the Lithium batteries.
That’s definitely out of the box! š
What appliances do you plan on running on 240V ?
Congrats guys, this is very cool!
Would you mind me asking how you do your web design? Are you writing in Python or some other language?
Yeah sure!
Platform: Wordpres
Hosting:SiteGround
Theme: GeneratePress
Builder: Elementor
The only “code” we’ve got on this website is the calculator, it’s written in JavaScript.
VoilĆ !
š
Amazing resource! Iām planning on doing the alternator connected to a battery to battery charger connected to a 200ah Renogy 12v battery. I have a 2006 dodge sprinter with a 150A alternator output. Iām having a hard time finding any resources that tell me the sprinterās amperage to get the Amps available on the alternator. I used your calculator and tried various options (60A-90A) and received a āup to 40A battery chargerā. I see that Renogy only makes a 20A and 40A. Is there a difference or recommended battery charger? If it says up to 40A, would 40A be too much? Is 20A the best option? Also, does your diagram show how to connect the battery to battery charger to the alternator? A person was helping me convert my van but ending up being a scam artist and now Iām left with partial wiring. Trying to figure this out on my own! Any help would be appreciated!
Hi Alyse,
A 200A AGM battery should be charged at a rate of around 20% its capacity, hence 200 x 0.2 = 40A.
Therefore, a 40A Renogy B2B is your best option.
The Renogy owner’s manual will describe how to hook it to your van, and you can go on the Sprinter forum to get help from others fellow Sprinter owners: https://sprinter-source.com/forum/ (we personally converted a Transit, not sure about the Sprinter…).
Hope that helps!
Good luck,
antoine
Hi there –
First of all, I can’t tell you how incredibly helpful your site is. To the point, I’m having trouble wrapping my head around the difference between 12V and 120V. Additionally, what things actually run on 120V vs 12V. Looking at you 120V list it’s much smaller, but in my mind, all of those things plug into a standard 12V outlet, right? Anyway, I’m starting to fill out your extremely handy calculator and want to make sure I’m taking everything into account so any additional information would be great. Thanks again!
Hi Tucker,
We listed all our 12V loads here: https://faroutride.com/electrical-system/#12v_loads
And I think this should help you understand 12V vs 120V: https://faroutride.com/electrical-system/#120v_loads
Try to minimize your 120V appliances as it’s less efficient than 12V.
Hope that helps!
antoine